RussianEnglish (United Kingdom)

 

ЮГРЕФТРАНСФЛОТ”   YUGREFTRANSFLOT
ПУБЛИЧНОЕ АКЦИОНЕРНОЕ ОБЩЕСТВО  PUBLIC JOINT – STOCKCOMPANY

SHIPMANAGEMENT DEPARTMENT

PROCEDURE No. 38

PREVENTION OF AIR POLLUTION BY OZONE DEPLETING SUBSTANCES

New rules for prevention of air pollution from ships entered into force on 19.05.2005. These rules forbid deliberate emission of ozone depleting substances/ODS from ships. According to the company’s policy “Green House Gas”, special attention should be paid to the efficient control for use of ozone depleting gases like R-22, Suva and other refrigerants on board ships according to item 1-8 and control their emissions.

  1. In order to provide maintenance or service to any refrigerating equipment a receiver as a recovery equipment should be used.

  2. Upon completion of repair/ maintenance the system should be pumped out by vacuum pump.

  3. Refilling of single-use cylinders is forbidden.

  4. All above mentioned services are to be recorded in reefer logbook.

  5. Annual leakage of refrigerants from main refrigerating plant, provision rooms, air conditioning systems should be less than 10 % of quantity filled in systems and its quantity to be recorded in logbook.

  6. Quantity of refrigerant leakage to be considered as the difference between quantity of added refrigerant in system and quantity of recovered to receiver refrigerant during maintenance.

  7. Refrigerant leakage to be recorded in a tabular form every month within the year and contain following information:

  • Date

  • System type/ main refrigerating plant, provision rooms system, air conditioning system

  • Type of refrigerant

  • Initial system filling-in

  • Quantity added

  • Quantity recovered

  • System inspection

  • Remarks / follow up

  • Quantity and type of oil

  • Quantity of oil added and replaced

  • Signature

Reports on refrigerant static leakage and maintenance of equipment and systems containing ozone depleting substances to be submitted to ship management department at the beginning of every month. Accidental emission of refrigerant shall be reported to shipmanagement department immediately.

Note:R-12 refrigerant is forbidden for use.

Fleet Manager Viktor Kot